Nvent caddy mac2 snap in cable support for mc ac cable and flexible conduit snap in support mc ac cable flexible conduit metal or wood stud and up to 1 8 inch flange standard packaging quantity.
Mc cable support spacing.
In length from the last point of cable support to the point of connection to a luminaire or other.
The above supports must be located at a maximum distance of 1 22m 48 inches in both the horizontal and vertical orientations.
These cable supports offer a time saving optional re entry design.
Mc cables may be unsupported when 1 fished through concealed spaces in finished buildings 2 when not more than 6 ft.
Secure non metallic and metal clad cable to wood or metal studs with the caddy 9 in.
Cable support spacing.
Cable and cable sealing fittings for hazardous classified locations is the industry standard for this listing.
There are a number of changes in the 2002 national electrical code nec regarding metal clad type mc cable that should be reviewed before your next electrical project.
Additional wedge type supports shall be permitted to relieve the strain on the equipment terminals caused by expansion of the cable under load.
In order to be labeled for division 1 hazardous locations type mc hl by ul the c l x cables must meet the following criteria.
The versatile z shaped design of the b line series conduit trapeze support allows for quicker installation and support of multiple sizes of conduit mc ac cable cable tray and other accessories such as electrical boxes.
In the 1999 nec article 334 covered type mc cable.
Mc cable must be supported every 6 ft.
Type mc cable can be unsupported where the cable is.
Until you become familiar with the new location in the nec it may take some searching to find it.
1 fished through concealed spaces in finished buildings or structures where support is impracticable or 2 not more than 6 ft long from the last point of cable support to the point of connection to luminaires or other electrical equipment within an accessible ceiling.
To hold the cable in the event there is slippage of the cable in the wire armored cable support.
The solution installs up to 50 quicker than traditional strut trapeze and the conduit holes automatically align conduits across the trapeze.
Nonmetallic sheathed cable shall be supported and secured by staples.
Or straps hangers or similar fittings designed and installed so as not to damage the cable at intervals not exceeding 1 4 m 4 ft and within 300 mm 12 in of every cable entry into enclosures such as outlet.
This standard mandates performance tests more stringent than those required for type mc cable.
American connector per fit type wt wse.
B fire rated cables and conductors.
Cable ties listed and identified for securement and support.
Support methods and spacing intervals for fire rated.
Use a ulc listed brass stainless steel or nickel mc connector suitable for a corrugated copper sheath suggested sources.